Polyair Performa is a high grade radiant heat barrier that can boost the thermal performance of roofs and walls , improving the comfort and energy efficiency of a structure.

Polyair Performa is a multi layered thermo reflective insulation product. Its special antiglare coated foil reflects up to 91% of the sun’s radiant heat while the foam inner core and inward facing foil reduces heat transfer through the product.

CSR Polyair - Thermo Reflective Insulation

AU$195.00Price
LENGTH
  • Specifications Table

      Thickness (mm) Roll Size (m x mm) m2 Per Roll (m2) Roll Diameter (mm) Roll Weight (kg) Product Code
    Performa 4.0 4 20 x 1350 27 380 9 118113
    4 40 x 1350 54 500 14 123974
    Performa 7.0 7 30 x 1350 40.5 600 18 123691

    Classifications

    PROPERTY REFERENCE RESULT
    Emittance AS/NZS 4201.5:1994/ASTM E408 Double-sided reflective
    Antiglare Face E0.09
    Silver Face E0.03
    Material thermal resistance ASTM C518 0.1m² K/W Performa 4.0
    0.2m² K/W Performa 7.0
    Resistance to dry delamination AS/NZS 4201.1:1994 Pass
    Resistance to wet delamination AS/NZS 4859.1 (App I) Pass
    Surface corrosion AS/NZS 4859.1 (App I) Pass
    Fire – BCA Classification AS/NZS 3837:1998 Group 1
    Flammability index AS 1530.2 Low (≤5)
    Early fire hazard Indices AS/NZS 1530.3  
    Ignitability AS/NZS 1530.3 0
    Spread of flame AS/NZS 1530.3 0
    Heat evolved AS/NZS 1530.3 0
    Smoke developed AS/NZS 1530.3 0-1

     

    Total R-Value Performance:

    Flat Metal Roof Flat Metal Roof
    Metal roof 1° pitch Metal roof 1° pitch
    15mm airspace (generic spacer) 60mm airspace (Ashgrid spacer)
    Bradford Polyair Performa 7.0 Bradford Polyair Performa 4.0
    (with slight dust cover) (with slight dust cover)
    Min 300mm non-ventilated airspace Min 300mm non-ventilated airspace
    13mm plasterboard ceiling 13mm plasterboard ceiling
       
    Heat flow in (summer) = RT3.2 Heat flow in (summer) = RT3.5
    Heat flow out (winter) = RT1.3 Heat flow out (winter) = RT1.3

     

    Total R-Value Assumptions

    The contribution of Polyair to a Total R-Value depends on the installation and environmental conditions. The Total R-Value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated. Thermal calculations are based on Australian parameters and in accordance with AS/NZS 4859.1:2002/Amdt.1. The contribution of Polyair towards the Total R-Value depends on installation and environmental conditions. For upward facing surfaces of horizontal or sloping reflective insulation in non-vented cavities where no special precautions for prevention of dust ingress have been included, the Total R-Value is calculated based on an emittance for the case of dust cover in accordance with AS/NZS4859.1 Paragraph K3.2(a)(ii), unless otherwise stated. For calculation purposes, the air gaps are assumed as still parallel air gaps unless otherwise stated and the membrane continuous.